BXWVZ - 302B0250, CATHA-COAT 302 REINFORCED (SUPDAT)

  • MSDS: BXWVZ
  • Manufacturer: DEVOE COATINGS CO
  • Product Name: 302B0250, CATHA-COAT 302 REINFORCED (SUPDAT)
  • National Stock Number: 8030-00N034143
Product Identification

Product ID:302B0250, CATHA-COAT 302 REINFORCED (SUPDAT)
MSDS Date:04/07/1993
FSC:8030
NIIN:00N034143
MSDS Number: BXWVZ

Responsible Party
DEVOE COATINGS CO
4000 DUPONT CIRCLE
LOUISVILLE, KY 40207
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 502-897-9861

Cage: 1HK86

Contractor
DEVOE COATINGS CO
7600 LOUISVILLE, KY 40207-4802 US

Telephone: 502-897-9861

Cage: 1HK86

Ingredients

WELDING & FLAME CUTTING ON SURFS COATED W/THIS PROD.

RTECS: 9999999ZZ


HEAVY SOLV VAPS FROM LOWER LEVS OF WORK AREA. ELIM

RTECS: 9999999ZZ


413.02 (GRAMS/LITER)

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


NEAR CNTNR (EVEN EMPTY) AS PROD/ITS RESIDUE MAY

RTECS: 9999999ZZ


CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT.

RTECS: 9999999ZZ


VOMIT. ASPIR OF VOMITUS CAN CAUSE CHEM PNEUM

RTECS: 9999999ZZ


DELIBERATELY CONCENTRATING & INHALING CONTENTS MAY

RTECS: 9999999ZZ


SPK TOOLS. STORE IN CLSD CNTNR UNTIL PROPERLY

RTECS: 9999999ZZ


ABOVE 120F/NEAR FIRE/OPEN FLAME. STORE LG QTYS IN

RTECS: 9999999ZZ


CLSD WHEN NOT IN USE. DO NOT RANSFER CONTENTS TO

RTECS: 9999999ZZ


IF MATL PART OF 2 COMPONENT PROD, MIX OF BASE &

RTECS: 9999999ZZ


PROD MAY CNTN CHEM

RTECS: 9999999ZZ


REPROD HARM (PROPOSITION 65).

RTECS: 9999999ZZ


RESTRICTED VENT AREAS, NIOSH/MSHA APPRVD AIR

RTECS: 9999999ZZ


CUTTING, WELDING, BRAZING & SANDING MATL COATED WITH

RTECS: 9999999ZZ


HLTH STDS IN MIX, APPLIC & CURING AREAS & TO REMOVE

RTECS: 9999999ZZ


ZINC (SARA 313) (CERCLA)

CAS: 7440-66-6

RTECS: ZG8600000

Fraction By Weight: 50%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


BARIUM SULFATE

CAS: 7727-43-7

RTECS: CR0600000

Fraction By Weight: <50%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


PORTLAND CEMENT; (CEMENT)

CAS: 65997-15-1

RTECS: VV8770000

Fraction By Weight: 15%

OSHA PEL 50 MPPCF; Z-3

ACGIH TLV: 10 MG/M3 TDUST


(ORAL,RAT)1.62 GM/KG

CAS: 108-94-1

RTECS: GW1050000

Fraction By Weight: <5%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


EPOXY RESIN

CAS: 25068-38-6

RTECS: KC2100000

Fraction By Weight: 10%

OSHA PEL N/K

ACGIH TLV: N/K


2.14.

CAS: 110-43-0

RTECS: MJ5075000

Fraction By Weight: 10%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


4.2.

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: <5%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:IRRIT OF RESP TRACT; HDCH,
NAUS, DIZZ, WEAK & FATG. EXTREME EXPOS CAN RSLT IN UNCON & EVEN
RESP ARREST. SKIN/EYE CONT:CAUSES EYE & SKIN IRRIT. MAY BE HARMFUL
IF ABSORB THRU SKIN. INGEST:CA N CAUSE STOM AND/OR INTESTINAL
IRRIT, NAUS, VOMIT & DIARR. CHRONIC:RPTS HAVE ASSOC RPTD & PRLNGD
OCCUP (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OVEREXPOS TO SOLVS W/PERM BRAIN & NERV
SYS DMG. PRLNGD/RPTD BRTHG OF SPRAY MIST AND/OR SANDING DUST OVER
PERIOD OF YEARS MAY CAUSE DUST DISEASE OF LUNGS.
Medical Cond Aggravated by Exposure:NONE, WHEN USED IN ACCORDANCE WITH
SAFE HANDLING & USE INFORMATION.

First Aid

First Aid:INHAL:IF DFCLTY IN BRTHG, LEAVE AREA TO OBTAIN FRESH AIR. IF
CONTINUED DFCLTY IS EXPERIENCED, SUMMON MED ASSISTANCE IMMED. IF
BRTHG CEASES, RESTORE USING APPRVD CPR TECHNIQUES & SUMMON MED HELP
IMMED. EYES:FLUSH IMMED W/LG AMTS OF WATER FOR @ LEAST 15 MINS.
GET MED ASSISTANCE. SKIN:WASH AFFECTED AREAS W/SOAP & WATER. REMOVE
SOILED CLTHG. GET MED ASSISTANCE IF IRRIT PERSISTS. DO NOT INDUCE
(ING 11)

Fire Fighting

Flash Point Method:SCC
Flash Point:80.0F,26.7C
Lower Limits:1%
Extinguishing Media:CO*2 DRY CHEMICAL, FOAM, OR OTHER NATIONAL FIRE
PROTECTION ASSOC (NFPA) APPRVD METH FOR TREATING CLASS B FIRE.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
SUMMON PROFESSIONAL FIREFIGHTERS. WATER SPRAY MAY BE INEFTIVE. IF
WATER IS USED, FOG NOZZ PREF. IF (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPK &FLAME. VAPS MAY CAUSE FLASH FIRE. VAPS MAY
IGNITE EXPLOSIVELY. VAPS MAY SPREAD LONG DIST &(SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT (FLAMES, HOT
SURFS, & ELEC, STATIC/FRICTIONAL SPK). PVNT BRTHG OF VAPS.
VENTILATE AREA. BEFORE ATTEMPTING CLEAN-UP, REFER TO HAZ CAUTION
INFO IN OTHER SECTIONS OF MSDS. CNT N SPILL MATL & REMOVE W/INERT
ABSORB & NON(ING 13)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPK & FLAMES. DO
NOT SMOKE. VAPS MAY IGNITE EXPLO. VAPS MAY SPREAD LONG DIST &
BEYOND CLSD DOORS.
Other Precautions:EXTING ALL PILOT LIGHTS & TURN OFF ALL SOURCES OF
IGNIT INCLDG HEATERS, FANS & OTHER NON-EXPLO-PROOF ELEC EQUIP,
DURING USE & UNTIL ALL VAPS ARE GONE. PVNT BUILD-UP OF VAPS BY
MAINTAININIG CONTINUOUS FLOW OF FRESH AIR. DO NOT STORE (ING 14)

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPS, SPRAY MIST/SANDING DUST.
WHEN SPRAY APPLIED IN OUTDOOR/OPEN AREAS, & DURING SANDING/GRINDING
OPERATIONS, NIOSH/MSHA APPRVD MECH FILTER RESP TO REMOVE SOLID
PARTICLES OF OVERSPRAY & SANDING DUST. WHEN USED IN (ING 19)
Ventilation:PROVIDE GEN DILUTION/LOC EXHAUST VENT IN VOL & PATTERN TO
KEEP AIR CONTAMINANT CONC BELOW CURRENT APPLIC SFTY & (ING 21)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:SOLV IMPERMEABLE CLTHG & BOOTS. ANSI APPRVD
EMERGENCY EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:REMOVE & WASH SOILED CLTHG BEFORE REUSE. WASH
HANDS BEFORE EATING/SMOKING.
Supplemental Safety and Health
MFR TRADE NAME/PART NO:INORG ZINC PRIMER GREEN BASE. FIRE FIGHT
PROC:EXPOS TO FIRE/EXTREME HEAT, WATER SHOULD BE USED TO COOL CLSD
CNTNRS & PVNT PRESS BUILD UP/POSS AUTO-IGNIT. EXPLO HAZ:BEYOND CLSD
D OORS. DUE TO PRESS BUILD-UP, CLSD CNTNRS EXPOS TO EXTREME HEAT
MAY EXPLODE. NEVER USE WELDING/CUTTING TORCH ON/ (ING 9

Chemical Properties

Boiling Pt:B.P. Text:>244F,>118C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:2.18
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NOT KNOWN
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:48.74

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CARBON MONOXIDE, CARBON DIOXIDE,
ZINC CMPDS.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE AND FEDERAL REGS.
INCIN ONLY IN APPRVD FACILITY. DO NOT INCIN CLSD CNTNRS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.